Product Details:
Payment & Shipping Terms:
|
Model Number: | GAG-3003A | Usage: | Battery Testing Machine |
---|---|---|---|
Steel Needle: | Dia 3mm ~ 8mm High Temperature Steel Needle, Length Of 100mm | Acupuncture Stroke: | 200mm Or 300mm |
Penetration Speed: | 0 ~ 80mm/s(controllable), 200 Mm/s Can Be Customized | Power Source: | AC380V 50HZ 3P5W |
Driven Method: | Hydraulic | Power: | Electronic |
High Light: | battery charge discharge test equipment,automotive battery testing equipment |
Automobile Lithium Battery safety Needle Punching Test Machine TESLA Vehicle Testing
Description
Digital Battery Acupuncture Tester, Battery Safety Puncture Testing Machine is suitable for simulation of various types of batteries in the transport, storage process by acupuncture. The test shall be carried out at an ambient temperature of 20 ° C ± 5 ° C. The battery of the thermocouple (the contact surface of the thermocouple is fixed on the large surface of the battery) shall be placed in a fume hood with a stainless steel with a diameter of 2-8 mm The needle at 10mm / s ~ 40mm / s speed piercing the battery maximum surface of the central position, to maintain any time and observe the test results, the battery does not explode, do not fire for qualified.
Specifications
Auxiliary Function | Voltage, temperature sampling, camera monitoring system. Fire-extinguishing system, smoke evacuation & filtering system | |
Penetration Speed | 0 ~ 80mm/s(controllable), 200 mm/s can be customized | |
Test Zone(mm) | 200X200X200MM,600X600X600MM,800X800X800MM,1000X1000X1000MM (Available to customize) | |
Overall Dimension | Subject to actual design and manufacture | |
Optional Parameters | Voltage Range | 0—10V,0--100V,0—1000V |
Temperature Sampling Range | 0 ~ 1200℃ | |
Voltage, Temperature Accuracy | ±1%FS | |
Voltage Resolution | 1mV | |
Temperature Resolution | 0.1℃ | |
Standard Parameter P Par |
Speed | 0 ~ 80mm/s(Controllable), 200 mm/s (Available to customize) |
Nail Travel | 0—1000MM to select | |
Structure | Vertical & horizontal (select according to actual size) | |
High Temperature Nail Regulation | Diameter φ3mm~φ8mm | |
Nail Penetration Method | Horizontal, vertical | |
Nail Deformation | No (Computerize can be customized) | |
Nail Remaining Time | 0~99 H 99M 99S | |
Driven Method | Hydraulic | |
Nail Penetration Speed | ±0.1MM/S | |
Force Accuracy | ±1% | |
Structure | Chamber | Independent vertical & horizontal test machine and control system |
Communication | No (computerize can be customized) | |
High-temperature Nail | Diameter φ3mm~φ8mm (available to customize) | |
Data Acquisition Module | Independent remote sampling, multi-voltage, temperature, current acquisition channel (optional) | |
Channel Quantity Configuration | 2-Channel, 4-Channel, 8-Channel, multi-data acquisition system (optional) | |
Camera Monitoring System | Test zone installed with high definition camera monitoring system in remote control with explosion-proof (optional). | |
Standard Configuration | Nail Penetration Machine/1 set, control cabinet/1 set, diameter φ3mm~φ8mm, high temperature nail/1 set | |
Test Fixture | Customize according to actual size | |
Power Source | AC380V 50HZ 3P5W | |
Working Environment | 0℃~45℃ |
Standard
GB/T 31467.3-2015,GB/T 31485-2015,GB 31241-2014,GB/T 18287 -2013,GB/T 8897.4-2008,YD/T 2344.1-2011,GB/T 21966-2008,MT/T 1051-2007,YD 1268-2003,GB/T 19521.11-2005,YDB 032-2009,UL 1642:2012,UL 2054: 2012,UN38.3(2012),IEC62133-2012,
IEC 62281: 2004,IEC 60086: 2007,GB/T 18332.2-2001 , MT/T 1051-2007, etc.