Product Details:
Payment & Shipping Terms:
|
Model Number: | GAG-3015A | Usage: | Battery Anti Explosion Tester |
---|---|---|---|
Burner: | Diameter 9.5mm Or 38mm, Length 100 Mm | Flaming Combustion Time: | 0~ 999, 999 Seconds ±0.1second |
Flame Height: | 10~75±2mm | Ignition Devices: | Automatic Ignition |
Fuse: | 3A | Power: | Electronic |
High Light: | automotive battery testing equipment,cell phone battery testing equipment |
Ul1642 HEV,BEV,FCEV Explosion Proof Battery Over Charging And Discharge Safety Testing Machine
Description
Explosion-proof chamber is mainly used for charging and discharging of battery. Put the battery in explosion-proof chamber and connect charge and discharge tester to protect the operator and equipment. The body is made of steel material with strong texture and well explosion protection.
The chamber provides explosion and flame proof function for battery to do overcharge and over discharge test. And the tester is divided in three layer with three test chamber. Test result is non-explosion, no fire, no air leaking, non-electrolyte leakage for the qualified battery.
1 | Flame exposure test |
2 | Burning particles test |
3 | Ejectisome test |
4 | Projectile test |
5 | Explosion test |
6 | Electronic ignition function |
7 | Explosion-proof |
8 | Timing |
Specifications
Model | GAG-3012 | GAG-3012A | GAG-3012B | GAG-3012C |
Burner | The UL burner, caliber diameter 9.5mm or 38mm, length 100 mm | |||
Flaming combustion time | 0~ 999,999 seconds ±0.1second | |||
Flame height | 10~75±2mm | |||
Testing Cover Width | 24″(610mm) , octagon shape(could be customized) | |||
Test cover highly | 12″(305mm) (could be customized) | |||
Ignition devices | remote control ignition, test process automatic control Remote wire-controlled distance: no barrier, 10 meters |
|||
Burning gas | Propane gas, Liquefied petroleum gas or methane | |||
Mesh Material | Stainless steel | |||
Working temperature range | 0ºC~40ºC | |||
Power supply | AC 220V/50HZ | |||
Consumption | ≤750W | |||
Fuse | 3A | |||
Safety indicators | Insulation resistance: shell, power input terminal are greater than 2MΩ. | |||
Pressure resistance: 1 seconds resistance voltage 1750V between the input power supply and the shell, whole current 10mA |
||||
Grounding: the power grounding electrode, the resistance between the shells is less than 0.1Ω |
||||
Fire extinguisher | manual CO2 fire extinguisher | |||
Customized service | Welcome to Non-standard, Special requirements, OEM/ODM orders. |
Features
1.Double columns design of hammer drop so as to reduce friction between hammer and the wall to achieve free falling, and effectively prevent the safety problems (The normal factory design is using brake motor which has major safety problems, The heavy hammer which hanging at the height possible automatically fall when the brake motor is power off, that will be safety problem of the operator.) Gaoge design effectively prevent the safety problem of this kind of the existence and appearance also perfect.
2.Impact weights can be changed over, mounting, dismantling in an easy way that provides an excellent solution to treat the error due to secondary impacts and improve the test accuracy.
3.The wire enclosed with metal fire-proof cover, which is available to prevent the flame during testing process.
4.Lighting system is designed to observe the internal testing process.
5.Height can be display in a digital way with controllable height from 0-1200mm.
6. Be equipped with the exhaust air vent (it is convenient for customers to discharge the odor produced in the battery test to the outside of the laboratory).
7.Control system employs independent control cabinet & separated with the test chamber with a distance 1-2 meter, which can reduce the noise and improve safety and Easy operation.
8. Double-layer explosion-proof glass window and explosion-proof chamber.
Standard
GB/T31467.3-2015,GB/T31485.3-2015, B/T4857.5-92,IEC62133,UN38.3,ISO02448-1972E,QC/T743,QC/T744
SJ/T11170-1998; SJ/T11169-1998; UL1642-2009, UL2054:2008; UL1642:1995; UN38.3