Product Details:
Payment & Shipping Terms:
|
Model Number: | GAG-3005 | Usage: | Short Circuit Test Machine |
---|---|---|---|
Applicable Industry: | Battery Industry | Device Loop Resistance: | ≤20mΩ Or ≤5mΩ |
Mechanical Endurance: | 300000 Times | Max. Short Circuit Current: | 1000A |
Internal Resistance System: | 5mΩ, 80±20 MΩ | Temp. Range: | 0℃ ~ 80℃ |
High Light: | battery charge discharge test equipment,cell phone battery testing equipment |
Programmable Lithium Ion Battery Short Circuit Testing Machine With UL 2054
Description
Single lithium ion battery forced internal short circuit testing machine also called batteries to forced internal short circuit tester is combined temperature control chamber and compression testing machine.
The forced short circuit testing machine, as a new type of testing equipment, can not only simulate test environment, but detect test data of specimen under specific environment.
battery internal short circuit testing machine is preferred instrument for testing batteries, capacitors, electronic products.
Specifications
Temperature control system technical parameters | |
temperature range | -10 ℃ ~ 100 ℃ |
analytical accuracy | 0.1 ℃ |
temperature fluctuation | ± 0.5 ℃ |
temperature uniformity | ± 2 ℃ |
heating rate | 3 ℃ / min |
cooling rate | 1 ℃ / min |
inner box size | 500x500x600mm (length x width x height) |
inner box material | 304 stainless steel plate, the bottom to strength |
Outside size | 1050x1500x2100mm (length x width x height) |
Temperature control system | TEMI880 or TEMI580 |
The pressure system technical parameter | |
test load | commonly used 80Kg (maximum 100Kg) |
load resolution | 1/10000 |
unit conversion | Kg, lb, N |
load accuracy | FS ≤ ± 0.5% |
resolution | ± 0.5% |
displacement accuracy | ± 0.05mm |
speed range | 0.01 ~ 20mm / s adjustable (commonly used test speed 0.1mm / s) |
effective travel | 100mm |
test plane | 200x200mm (can be customized) |
the voltage acquisition range | 0 ~ 20V |
voltage resolution | 0.1mv |
the voltage acquisition frequency | 100 times / s |
indenter size | 5x5x2mm or 10x10x2mm or 10x10x15mm |
indenter material | Nitrile butadiene rubber,acrylic each one piece |
acrylic | PLC control |
Features
1. Temperature control box :
1.1 Perfect modeling design: the arc shape and surface coating processing, elegant appearance, fitted with safe handle, easy to operate, reliable and safe.
1.2 Bright, broad field of vision of large observation window: use double vacuum coating Windows and energy-saving fluorescent philips lamps, no need wiper mist, keep clear observation of the effect of the sample (s) to observe the situation.
1.3 Advanced and reliable refrigeration and control system: closed compressor imported from Europe and the United States, imported eco-friendly refrigerant, the world famous brand refrigeration devices, original imported LED button type controller, and the operation is simple to learn.
1.4 Has the function power off to stop function.
1.5 Has a fault alarm, test-over alarm
1.6 Exhaust emissions system: on the top of chamber, fitted with exhaust vent and powerful exhaust fan. Vent is closed when not in use, open when waste gas discharge. Waste gas can be quickly outside.
2. Pressure test system:
2.1 Power system:
Japan panasonic ac servo motor
Panasonic ac drives
the worm gear and worm reducer
high precision ball screw imported from Taiwan.
2.2 Control system:
using Pulse Command control mode control more accurate;
speed control range: 0.01 to 200 mm/S.
the intermediate plate adjustment can be fast rough adjustment and fine tuning.
After testing, automatically return to the origin, automatic storage;
2.3 Data transmission mode:
the RS232 transmission.
One-step and precision seven-step dual force linear calibration system.
test interface software which can be set speed, displacement, load, and holding time
Settable load rate, stress rate, strain rate and multi-stage control mode can be meet with different testing requirements.
2.4 Safety device:
the overload emergency stop device;
travel up and down limit device;
automatic breakpoint stop function.
2.5 Stop function:
Stop function to voltage. When tested battery is connected with external voltage. The testing machine can be set voltage value to shutdown. Output signal when voltage of two ends of battery reduces to set value, and system will stop action.
Standard
QC/T 743-2006 Lithium ion battery for electric vehicle
QC/T 744-2006 Metal hydride nickel batteries for electric vehicles
GB/T 31467.3-2015 Lithium ion power battery pack and system for electric vehicle -
Part 3: Safety requirements and test methods
GB/T 31485-2015 Safety requirements and test methods for power batteries for electric vehicles
GB/T 31241-2014 Safety requirements for lithium ion battery and battery pack for
portable electronic products
GB/T 8897.4-2008 Part 4 of the primary battery safety requirements of lithium batteries
YD/T 2344.1-2011 Lithium iron phosphate batteries for communication - part one: integrated batteries
GB/T 21966-2008 Safety requirements for lithium primary batteries and batteries in transit
MT/T 1051-2007 Lithium ion battery for miner's lamp
YD 1268-2003 Safety requirements and test methods for lithium batteries
and chargers of mobile communication handsets
GB/T 19521.11-2005 Safety code for inspection of hazardous features of lithium battery pack
YDB 032-2009 Backup lithium ion battery for communication
UL 1642:2012 Lithium battery standard
UL 2054: 2012 Household and commercial battery pack
UN38.3(2012) Recommendations on the transport of dangerous goods -
Test and standard manual part 3
IEC62133-201 Safety requirements for battery and storage battery with alkaline
or non acid electrolytes
IEC 62281: 2004 Safety requirements for lithium primary batteriy and battery pack in transit
IEC 60086: 2007 Primary battery part 4 safety requirements of lithium battery